射頻探針
67A (DC - 67 GHz)

Model 67A 射頻能力:DC-67GHZ;

分GSG、 GS 、SG 三種類型;
針尖不可替換;
引腳間距 25 to 1250 microns 可選。

  • 規格參數
  • 資料下載


High Performance Microwave Probes

Model 67A

Features
  • Coplanar probe tips
  • Any pitch from 25 to 1250 microns
  • Durable
  • DC to 67 GHz
  • Insertion loss less than 1.1db
  • Return loss greater than 14db
  • Measurement repeatability -80db
  • Individually spring loaded contacts
  • BeCu or Tungsten tips available
  • Variety of Footprints
  • Patented coaxial design
  • Available in thirteen styles
  • Custom configurations available


  • A coplanar probe with patented flexible tips, the MODEL 67A microwave probe sets new standards in microwave probing performance. Using low loss coaxial techniques, the Model 67A achieves an insertion loss of less than 1.1 db and a return loss of greater than 14 db through 67 GHz.

    With its individually spring loaded, Beryllium-Copper or optional Tungsten tips, the Picoprobe® Model 67A microwave probe provides reliable contacts, even when probing non-planar structures. This reliable low resistance contact is one of the keys to providing highly repeatable measurements. The Model 67A also provides direct viewing of the probe tips for accurate positioning.

    The Model 67A can be mounted in various adaptors for use with standard microwave probe stations. Custom mounts are available.

    Any pitch (tip spacing) from 25 to 1250 microns may be specified. The probe can be configured with Ground-Signal-Ground (G,S,G), Ground-Signal (G,S), or Signal-Ground (S,G) tip footprints. We recommend smaller pitches with a G,S,G footprint for best results.

    Connection to the Model 67A is through a female V connector.

    Flexible Tips for Flexible Probing

    Each Model 67A has patented, independently spring loaded tips which make contact to the probing surface. Because the tips are flexible they minimize circuit damage, increase probe life, and most importantly, provide a reliable individually spring loaded contact for each point. With a small amount of overdrive, the point scrubs the surface to make a reliable contact free of dust, dirt, and oxide contamination. The ability to view the exact contact area eases probe positioning and allows for the precise positioning necessary for good LRM calibrations. The flexible tips even allow probing of non-planar surfaces such as ceramic substrates and laser diode structures.

    Coaxial Transmission Improves Performance

    The Model 67A uses a precision miniature 50 ohm coaxial cable from the probe tips to the connector interface. The coaxial design provides lower loss and less radiation than traditional coplanar designs. The miniature coaxial cable is fabricated from flexible Beryllium-Copper which greatly improves the probe’s durability.

    Probe Cards

    Model 67A probes can be mounted on both standard 4.5 inch probe cards and custom-sized probe cards to provide a convenient method for testing wafers at high frequencies using standard automatic or manual probe stations. Picoprobe Probe Cards combine our Model 67A probe technology for RF connections with DC needles for power and low frequency signals.

    Multi-Contact Wedges

    Our unique Multi-Contact Wedge designs accommodate multiple RF and DC contacts on a single, compact adapter. This compact design provides the user with a convenient method for testing wafers at high frequencies using standard automatic or manual probe stations. The user can choose from a variety of wiring options for the DC or power needles and select any combination of 40, 50, 67, and/or 110 GHz RF probes.



    FIGURE 2

    Line of Microwave Probes

    An entire line of microwave probes are available with standard tip spacings of up to 2540 microns. Larger tip spacings are available as well. For special applications, the Model 67A can be mounted in custom adaptors, the coaxial line can be bent to fit tight spaces, and the tips can be configured to match extremely non-planar surfaces or non-symmetrically placed grounds.

    Other options include:
    Tungsten or Nickel probe tips;
    high temperature and high power versions;
    custom "chip" probes which have integrated series, parallel or termination components built into the signal tip.

    For applications below 40 GHz, GGB Industries, Inc., offers the Model 40A Picoprobe which uses the 2.9mm K connector. The Model 40A performs up to 40 GHz with less than 0.8 db insertion loss and return loss of greater than 18 db.

    For applications above 50 GHz, GGB Industries, Inc., offers a complete line of microwave probes operating up to 325 GHz (Model 325). Several models are available with wave guide inputs: WR-22 for 33 to 50 GHz, WR-15 for 50 to 75 GHz, WR-12 for 60 to 90 GHz, WR-10 for 75 to 120 GHz, WR-8 for 90 to 140 GHz, WR-5 for 140 to 220 GHz, and WR-3 for 325 GHz. The wave guide probes have an optional integral Bias T for active device measurements.  Many other types and custom designs are available, so please call with your special application requirements.

    Probing Expertise

    With more than 25 years of probing experience, GGB Industries has broad capabilities in custom probe engineering and manufacturing. Our staff is accustomed to creating unique solutions for the most difficult probing requirements demanded by our customers. GGB Industries, Inc., is the leading supplier of high impedance active probes offering models with input capacitances of as low as .02 pF and frequency responses of up to 26.0 GHz.

    ORDERING INFORMATION

    When ordering Model 67A probes, use the following part numbering convention:

    Model 67A - configuration - pitch - mounting style

    Configuration: Specify GSG, GS or SG for tip placement where S is the signal tip and G is a ground tip. Use the following diagram to determine the appropriate configuration.

    Pitch: Specify ground (G) to signal (S) tip spacing in Microns from 50 to 1250 microns. For standard GSG probes, the two spacings are equal. Contact the factory for spacings larger than 1250 microns or unusual tip placement and spacings.



    Mounting Style: Choose from thirteen adapter styles. Specify T, C, GR, P, DP, EDP, LP, Q, F, S, DS, VP, or RVP. Choose the appropriate mounting type for your application. The P, DP, EDP, LP, Q, S, DS, VP, and RVP styles have the connector pointing back at a 45 degree angle to give more working area above the probe. The DP, EDP, DS, VP, and RVP styles are used where extra clearance beneath the probe is needed. When using DP, EDP, and DS style probes, probe positioning is more difficult due to the increased probing angle since the probe points slide further forward for a given change in the Z axis than our other style probes. Custom mounting styles are available
    Example:A 67A-GSG-150-P is a Model 67A with Ground, Signal, Ground configuration with 150 microns between each contact mounted in a P style adaptor.






    推薦產品
    主站蜘蛛池模板: 精品视频一区二区三区四区五区 | 91精产国品一二三区 | 国产av色区 | 中文AV伊人AV无码AV狼人 | 亚洲国产av无码精品果冻传媒 | 经典三级久久 | 国产精品内射久久久久欢欢 | 嫩草在线观看视频 | 一级bb片 | 91精品国产综合久久久久影院不卡 | 国产精品视频一区二区三区四区五区 | 2020日本不卡一区二区视频 | 亚洲 小说区 图片区 都市 | 精品国产一区二区三区av 性色 | 成人做爽爽爽爽免费国产软件 | 亚洲精品愉拍自偷一区二区三区 | 奇米四色影院 | ZZIJZZIJ亚洲日本少妇 | 野花日本大全免费观看 | brazzershd肉感大屁股 | 麻豆激情 | 一个人在线观看免费视频www | 久久综合给合久久狠狠狠97色69 | 九九视频一区二区 | 欧美13一14娇小性 | 无码一区二区三区在线观看 | 西西人体大胆午夜啪啪 | 少妇大叫太大太粗太爽了A片软件 | 91日日拍夜夜嗷嗷叫国产 | 亚洲精品无码专区在线播放 | 国产主播在线一区二区 | 国产高清黄色片 | 免费观看又色又爽又黄的韩国 | 奶涨边摸边做爰爽别停快点文 | 一级特黄免费 | 短文合集高h肉汁bl 99re热在线视频 | 强女の上司侵犯在线观看 | 国产品久久久久久噜噜噜狼狼 | 2019亚洲午夜无码天堂 | aaaaaaa片毛片免费观看 | 乳揉みま痴汉电车中文字幕 |